Go to Machine Design Home Go to GlobalSpec.com Home
Find:      Advanced >>
Alert   Product Alerts
Keep current on the latest products, new suppliers, and technical articles of interest to you. (See Topics)

Tyco Thermal Controls - Sensing cable for liquid hydrocarbon fuels TT5000

For More Products
Print Print
See Product Details

TT5000 sensing cable provides distributed leak detection and location for a wide range of applications. The cable is available in a variety of lengths to provide as much coverage as needed.

TT5000 sensing cable is available in bulk reels, with connector kits or with factory installed connectors that plug together. The cable is designed for a variety of double containment applications, including tanks, trenches, and piping.

The Raychem radiation-cross linking and conductive-polymer technologies are used to make TT5000 sensing cable mechanically strong and chemically resistant. The core of the cable is constructed of two sensing wires, an alarm signal wire, and a continuity wire.

The core is encased in a conductive-polymer jacket and surrounded with a fluoropolymer braid. This rugged construction allows the cable to perform reliably in the most demanding environments.

Product Characteristics

· Cable diameter 0.28 in (7 mm) nominal

· Cable diameter with connector 0.52 in (13 mm) nominal

· Cable weight (50 ft/15 m length) 2.4 lb (1.1 kg)

· Operating temperature range –4°F to 140°F (–20°C to 60°C)

· Pull force limit Not to exceed 50 lb (22.7 kg)

· Bend radius 2 in (50 mm) minimum

· Pressure Loads greater than 20 lb (9 kg) per linear inch at 68°F (20°C) may immediately trigger an alarm

· Non resettable must be replaced after exposure to hydrocarbon liquids

Chemical Resistance

Cable functions normally after exposure in accordance with ASTM D 543 at 73°F (23°C) for seven days

Sulphuric acid (10%)

Hydrochloric acid (10%)

Nitric acid (10%)

Sodium hydroxide (10%)

Water Resistance

Sensing cable Less than 10 μA leakage when immersed in salt water for 90 days

Connector system Less than 10 μA leakage when immersed in water at 10 psig for 24 hours

Response Times

• Response Time Test Method: "Test Procedures for Third Party Evaluation of Leak Detection methods; Cable Sensor Liquid Contact Leak Detection Systems."

• Response times are affected by operating temperature. Consult factory for specific response times at other temperatures and in other liquids. Represented materials detected Typical response time at 68°F (20°C)

Gasoline 12 minutes

#1 diesel fuel 60 minutes

#2 diesel fuel 120 minutes

JP5 jet fuel 70 minutes

JP8 jet fuel 50 minutes

Jet-A jet fuel 50 minutes

Xylene 20 minutes

Ordering Information

TT5000 zone sensing cable with factory-installed connector and end termination

Catalog number Description

TT5000–Zone–MC 5 ft (1.5 m) sensing cable with heat-shrink

end termination

TT5000 modular sensing cable with factory-installed connectors

Catalog number Description

TT5000–0.3M/1FT–MC 1 ft (0.3 m) sensing cable

TT5000–1.5M/5FT–MC 5 ft (1.5 m) sensing cable

TT5000–3M/10FT–MC 10 ft (3 m) sensing cable

TT5000–4.5M/15FT–MC 15 ft (4.5 m) sensing cable

TT5000–7.5M/25FT–MC 25 ft (7.5 m) sensing cable

TT5000–15M/50FT–MC 50 ft (15 m) sensing cable

TT5000–30M/100FT–MC 100 ft (30 m) sensing cable

TT5000 bulk sensing cable

for installation in double-containment piping (connector kits required)

Catalog number Description

TT5000–SC Bulk sensing cable on reel

Minimum length: 100 ft (30 m)

Maximum length: 800 ft (240 m)

Connector kits (not shown)

TT5000–CK–MC–M/F

(includes test tools)

Components for five mated pairs of

connectors

TT5000–CK–MC–M One pin-type connector

TT5000–CK–MC–F One socket-type connector

Part Saved

You've successfully added from to your part list.

Save part

Part Name / #:
Product Type:
Description:



©1999-2009 GlobalSpec. All rights reserved.
Use of GlobalSpec is governed by these Terms of Use and Privacy Policy.

Penton Media, Inc. Site Use Agreement :: Privacy Policy
Home :: Article Archive :: CD Library :: CAD Library :: Site Map