TT5000 sensing cable provides distributed leak detection and location for a wide range of applications. The cable is available in a variety of lengths to provide as much coverage as needed.
TT5000 sensing cable is available in bulk reels, with connector kits or with factory installed connectors that plug together. The cable is designed for a variety of double containment applications, including tanks, trenches, and piping.
The Raychem radiation-cross linking and conductive-polymer technologies are used to make TT5000 sensing cable mechanically strong and chemically resistant. The core of the cable is constructed of two sensing wires, an alarm signal wire, and a continuity wire.
The core is encased in a conductive-polymer jacket and surrounded with a fluoropolymer braid. This rugged construction allows the cable to perform reliably in the most demanding environments.
Product Characteristics
· Cable diameter 0.28 in (7 mm) nominal
· Cable diameter with connector 0.52 in (13 mm) nominal
· Cable weight (50 ft/15 m length) 2.4 lb (1.1 kg)
· Operating temperature range –4°F to 140°F (–20°C to 60°C)
· Pull force limit Not to exceed 50 lb (22.7 kg)
· Bend radius 2 in (50 mm) minimum
· Pressure Loads greater than 20 lb (9 kg) per linear inch at 68°F (20°C) may immediately trigger an alarm
· Non resettable must be replaced after exposure to hydrocarbon liquids
Chemical Resistance
Cable functions normally after exposure in accordance with ASTM D 543 at 73°F (23°C) for seven days
Sulphuric acid (10%)
Hydrochloric acid (10%)
Nitric acid (10%)
Sodium hydroxide (10%)
Water Resistance
Sensing cable Less than 10 μA leakage when immersed in salt water for 90 days
Connector system Less than 10 μA leakage when immersed in water at 10 psig for 24 hours
Response Times
• Response Time Test Method: "Test Procedures for Third Party Evaluation of Leak Detection methods; Cable Sensor Liquid Contact Leak Detection Systems."
• Response times are affected by operating temperature. Consult factory for specific response times at other temperatures and in other liquids. Represented materials detected Typical response time at 68°F (20°C)
Gasoline 12 minutes
#1 diesel fuel 60 minutes
#2 diesel fuel 120 minutes
JP5 jet fuel 70 minutes
JP8 jet fuel 50 minutes
Jet-A jet fuel 50 minutes
Xylene 20 minutes
Ordering Information
TT5000 zone sensing cable with factory-installed connector and end termination
Catalog number Description
TT5000–Zone–MC 5 ft (1.5 m) sensing cable with heat-shrink
end termination
TT5000 modular sensing cable with factory-installed connectors
Catalog number Description
TT5000–0.3M/1FT–MC 1 ft (0.3 m) sensing cable
TT5000–1.5M/5FT–MC 5 ft (1.5 m) sensing cable
TT5000–3M/10FT–MC 10 ft (3 m) sensing cable
TT5000–4.5M/15FT–MC 15 ft (4.5 m) sensing cable
TT5000–7.5M/25FT–MC 25 ft (7.5 m) sensing cable
TT5000–15M/50FT–MC 50 ft (15 m) sensing cable
TT5000–30M/100FT–MC 100 ft (30 m) sensing cable
TT5000 bulk sensing cable
for installation in double-containment piping (connector kits required)
Catalog number Description
TT5000–SC Bulk sensing cable on reel
Minimum length: 100 ft (30 m)
Maximum length: 800 ft (240 m)
Connector kits (not shown)
TT5000–CK–MC–M/F
(includes test tools)
Components for five mated pairs of
connectors
TT5000–CK–MC–M One pin-type connector
TT5000–CK–MC–F One socket-type connector