Emergency Stop Switches Specifications

What do you want to do?

Show All Emergency Stop Switches Companies

Learn more about Emergency Stop Switches

Search By Specification


Actuation




   Actuation Type       
   Your choices are...
 
      
 
   Pushbutton
 
     An operator uses the pushbutton to activate the contacts.  Typically these are large pushbuttons and are appropriately labeled as emergency stop switches.
 
   Telescopic Antenna
 
     Movement of the antenna in any direction will actuate the switch contacts and, by use of the appropriate equipment, stop the machine.
 
   Trip Wire (Rope Pull)
 
     Emergency stop cable-pull systems can be actuated at any point along the “trip wire.”  Some trip wire devices are designed to operate if the cable breaks or goes slack.
 
   Trip Wire / Pushbutton Combination
 
     Combination of trip wire and pushbutton design.  Typically they incorporate both a trip wire for actuation along any point of the cable and a pushbutton for emergency stopping at the end of the installation.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Minimum Operating Force (Trip Force)
 
     The minimum force required to initiate switching.
 
   Search Logic:      All matching products will have a value less than or equal to the specified value.
   Trip Wire (Rope Pull) Features      For Trip Wire (Rope Pull) Actuation Only.
   Your choices are...
 
      
 
   Right Angle Pull
 
     The trip wire must be actuated at a right angle from the switch body.
 
   Top Pull
 
     The trip wire must be actuated from the top of the switch body.
 
   Broken Cable Detection
 
     Broken cable, or slack, detection indicates when cable tension decreases from the pre-set tension.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Maximum Operating Distance (Rope Span):
 
     Typical cable span.
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
Switch Specifications




   Normally Open Contacts
 
     Normally Open - A relay contact pair that is open when the coil is not energized.
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Normally Closed Contacts
 
     Normally Closed - A relay contact pair that is closed when the coil is not energized.
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Changeover Contacts
 
     Changeover, Typically Form C (SPDT).
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Positive Break Contacts
 
     Also called Positive Opening Contacts; The contact point opens reliably and remains open in activated position even in the event of mechanical failure, such as breakage of a spring or contact welding.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
Electrical Switching Specifications




   Electrical Switching
 
     Used to isolate a machine's electrical power.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   Maximum Current Rating
 
     The maximum current rating of the switch.
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Maximum AC Voltage Rating
 
     The maximum AC voltage rating of the switch.
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Maximum DC Voltage Rating
 
     The maximum DC voltage rating of the switch.
 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
Pneumatic Switching Specifications




   Pneumatic Switching
 
     Used to isolate a machine's compressed air supply instead of electrical power.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   Pressure Range
 
     The pressure range of the pneumatic switch.
 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
Reset / Release Operation




   Reset / Release Operation      There are four types of reset (latching release) mechanisms.
   Your choices are...
 
      
 
   Automatic
 
     No reset action required (momentary).  Reset / Release should never be used to restart the machine.
 
   Pull to Reset
 
     The button or cable must be pulled to reset the switch and resume operation.
 
   Twist to Reset
 
     The button or cable must be twisted to reset the switch and resume operation.
 
   Pushbutton
 
     There is a reset pushbutton, which must be actuated to reset the emergency stop switch and resume operation.
 
   Key Switch
 
     The operator must use a key in order to reset the switch and resume operation.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Features




           
   Your choices are...
 
      
 
   Emergency Stop Label
 
     The emergency stop switch is clearly labeled as such.
 
   Explosion Proof
 
     Emergency stop switches are rated as explosion proof if they are constructed with housings that can withstand explosions.  This classification may also include housings, which can withstand sparking and flames.
 
   Hermetically Sealed
 
     Hermetic seals provide a vacuum or leak tight seal such as a brazed glass-to-metal seal.
 
   Illuminated Pushbutton
 
     The pushbutton is illuminated for visibility in low light situations.
 
   Integral Alarm
 
     An integral audio or visible alarm is provided with the emergency stop switch.
 
   Lockable
 
     Switch includes provision for locking in specified positions.
 
   Tamper Resistant
 
     The switch is provided with tamper proof measures to ensure it can only be altered by the appropriate personnel.
 
   Visual Indicator
 
     The emergency stop switch is supplied with a visual indication of operation, such as an LED to indicate power.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Environment




   Operating Temperature:
 
     The temperature range over which the device must operate.
 
   Search Logic:      User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria.
Find Companies by Name




©1999-2008 GlobalSpec. All rights reserved.
Use of GlobalSpec is governed by these Terms of Use and Privacy Policy.

Penton Media, Inc. Site Use Agreement :: Privacy Policy
Home :: Article Archive :: CD Library :: CAD Library :: Site Map