Go to Machine Design Home Go to GlobalSpec.com Home
Find:      Advanced >>
Alert   Product Alerts
Keep current on the latest products, new suppliers, and technical articles of interest to you. (See Topics)


Temperature Probes, RTD Specifications

What do you want to do?

Show All Temperature Probes, RTD Companies

Learn more about Temperature Probes, RTD

Search By Specification


Element Specifications




   Element Material       
   Your choices are...
 
      
 
   Platinum
 
     The most common metal used for RTDs - for measurement integrity platinum is the element of choice.
 
   Nickel/Nickel Alloys
 
     Very common metal used, economical but not as accurate as platinum.
 
   Copper
 
     Occasionally used as an RTD element. Its low resistivity forces the element to be longer than a platinum element. Good linearity and economical. Upper temperature range typically less than 150 degrees Celsius.
 
   Other
 
     Other, unlisted material such as Tungsten, silver, or gold.  Gold and silver are other options available for RTD probes - however their low resistivity and higher costs make them fairly rare.  Tungsten has high resistivity but is usually reserved for high temperature work.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Reference Resistance      When matching probes with instruments - the reference resistance of the RTD probe must be known. These are the most standard options available.
   Your choices are...
 
      
 
   10 Ohms
 
      
 
   100 Ohms (Most Common)
 
      
 
   120 Ohms
 
      
 
   200 Ohms
 
      
 
   400 Ohms
 
      
 
   500 Ohms
 
      
 
   1000 Ohms
 
      
 
   Other
 
     Other, unlisted reference resistance.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   # of Lead Wires Per Element      As lead wires increase - accuracy and repeatability tend to increase as well.
   Your choices are...
 
      
 
   2
 
     Device has 2 lead wires per element.
 
   3
 
     Device has 3 lead wires per element.
 
   4
 
     Device has 4 lead wires per element.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Element Configuration      The number of elements contained in the probe, typically the more elements in the probe the more accurate and expensive the probe is.
   Your choices are...
 
      
 
   Single Element
 
      
 
   Double Element
 
      
 
   > 2 Elements
 
      
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Sensed Temperature Range




   Sensed Temperature
 
     Sensed temperature is the temperature range for which the device is rated for sensing.
 
   Search Logic:      User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria.
Probe Configuration




   Probe Configuration       
   Your choices are...
 
      
 
   Straight Probe
 
     Straight probes measure stationary surface temperatures and can be used in wells.
 
   Penetration (Needle) Probe
 
     Penetration probes or needle probes are used to measure internal temperatures.
 
   Flexible Probe
 
     Flexible probes can be manipulated for various temperature measurements.
 
   Drop Probe
 
     Drop probes are designed for well or underwater temperature measurements.
 
   Curved Probe
 
     Curved probes are used to measure temperatures on pipes or other curved surfaces.
 
   Roller or Moving Probe
 
     Roller probes or moving probes measure temperatures on moving surfaces.
 
   Air Probe
 
     Air probes are designed for air-flow temperature measurements.
 
   Angled Probe
 
     Angled probes are used for temperature measurement applications inside pipes and angled spaces.
 
   Surface
 
     Surface probes attach to skin or a flat surface. They are also known as banjo, patch, or bolt-on probes. 
 
   Clamp or Strap Sensor
 
     Clamp probes or strap sensor probes clamp or wrap around the surface to be monitored.  
 
   Flat/Ribbon
 
     Flat probes or ribbon probes are temperature sensors with a flexible membrane.
 
   Other
 
     Other unlisted or specialized probe configurations.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Additional Probe Specifications




   Diameter or Width Range
 
     Depending on the probe configuration, this dimension is either the diameter or width of the probe, or the diameter of the object being monitored.
 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Sensitive Length
 
     Depending on the probe configuration, this dimension is either the height or length of the temperature-sensitive part of the probe.
 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Process Connection      There are many ways to connect a probe to a monitored process. This section describes standard connection methods, but is not an exhaustive list.
   Your choices are...
 
      
 
   None or Hand held
 
     Probes do not include a process connection. Typically, these devices are hand held probes.
 
   Bayonet
 
     Bayonet fittings consist of a socket with J-shaped slots on opposite sides. A bayonet base or coupling is inserted against a spring and rotated until its pins are firmly seated.
 
   Threaded Fitting
 
     Threaded fittings are continuous helical ribs, like on a pipe. Styles include national pipe thread (NPT), imperial or English, and metric. 
 
   Compression
 
     Compression fittings have a tapered sleeve and are used mainly with tube fittings.
 
   Braze, Weld or Solder
 
     Braze, weld, or solder fittings are designed to be brazed, welded, or soldered into place.
 
   Other
 
     Other unlisted or specialized process connections.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Sensor Termination Type      There are various methods for probe terminations. Sensor termination type is an important parameter when trying to match a probe with an instrument, transmitter or other signal conditioning equipment.
   Your choices are...
 
      
 
   Bare or Insulated Lead Wires
 
     Devices use bare or insulated lead wires.
 
   Metal Braided Leads
 
     Devices use metal braided leads.
 
   Armor Leads
 
     Devices use armor leads.
 
   Flexible Conduit Leads
 
     Devices use flexible conduit leads.
 
   Terminal Block
 
     Devices use terminal blocks. 
 
   Conduit Connector
 
     Devices use conduit connectors.
 
   Screw Tabs or Lugs
 
     Devices use screw tabs or lugs. 
 
   Integral Connection Head (Thermohead)
 
     Devices use integral connection heads (thermoheads).
 
   Plug or Quick Connect
 
     Devices use plugs or quick-connects.
 
   Other
 
     Other unlisted or specialized sensor termination type.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Features and Options




   Probe Features       
   Your choices are...
 
      
 
   Available as an Assembly
 
     Devices are complete or partial assemblies with a thermowell, fittings, and transmitter or thermohead.
 
   Cuttable
 
     Probes can be cut to specific lengths.
 
   Spring Loaded
 
     Spring loading ensures proper contact with the tip of the thermowell or the surface to monitor.
 
   Tip Sensitive
 
     With tip-sensitive probes, only the tip of the probe is temperature-sensitive.
 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Explosion Proof?
 
     Probes are rated as explosion-proof and can be used in hazardous environments.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   Splash Proof or Watertight?
 
     Probes are rated for washdown, splash, or direct immersion applications.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   HVAC Applications?
 
     Probes are designed specifically for heating, ventilation and air conditioning (HVAC) applications such as duct or flume monitoring.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   Sanitary Applications?
 
     Probes are designed specifically for sanitary applications such as food or pharmaceutical processing.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   Transmitter Output (e.g. 4-20 mA) ?
 
     Probes are configured with an analog current output, typically 4 - 20 mA.
 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
Find Companies by Name




©1999-2008 GlobalSpec. All rights reserved.
Use of GlobalSpec is governed by these Terms of Use and Privacy Policy.

Penton Media, Inc. Site Use Agreement :: Privacy Policy
Home :: Article Archive :: CD Library :: CAD Library :: Site Map